Equipment service

Testing & Diagnostics

Electrical and mechanical testing to investigate winding condition, insulation, vibration, temperature and motor failures.

Enquire about this service
Technician operating workshop equipment controls

A closer look.

Illustrative equipment, not a record of a particular IPS machine or project.

Use the left and right keys to rotate, up and down to tilt, and Home to reset the view.

Service Capabilities

Windings and insulation

Surge, Hi-Pot and insulation-resistance tests using Electrom equipment; winding analysis and offline partial-discharge testing.

Resistance and dielectric condition

Winding-resistance measurement with a Hioki DLRO meter and Tan-delta testing with Megger equipment.

Core and electrical behavior

Core-loss and hot-spot testing with a Phenix tester, plus inrush-current and speed testing.

Mechanical and thermal condition

Vibration analysis with an Adash analyzer, thermal-camera inspection and investigation of temperature-related problems.

Failure investigation

Root-cause analysis of motor failures.

Useful information

Which electrical and mechanical diagnostic tests are available?

IPS offers surge, Hi-Pot, insulation-resistance, offline partial-discharge, winding-resistance, Tan-delta and core-loss testing, along with vibration analysis and thermal inspection. The team discusses appropriate tests against the equipment condition.

How do I choose a test?

Describe the symptoms, operating conditions and any previous findings. Discuss the test requirement with the IPS team rather than selecting only from a test name.

Let’s get to work

Your equipment.
Our next conversation.

Share your equipment type, the issue and the service you need. Contact our team in Dammam to discuss your requirement.

Enquire about this service